Structural Systems
OverviewAccessing Structure SettingsLoad SetStructural AnalysisLFRS CriteriaStructural Analysis SettingsStructural SystemsFoundation SystemsSoil ParametersProduct Standardisation
Overview
In the building view, users can configure the structural design of a building from the Engineering Configuration. Podium automatically checks whether the chosen structural systems and products pass the structural checks.
Users can change configurations relating to:
- Load Set
- Structural Analysis
- Structural Systems
- Foundation Systems
- Soil Parameters
- Product Standardisation
Accessing Structure Settings
- Open your project and go to Engineering Config in the left sidebar.
- Select the configuration you want to edit (e.g. Podium Default).
- Open Structure.
- Choose the building type tab on the left: Industrial or Residential. Settings are saved separately for each.
Use the panel on the right to jump between Loads, Structural Analysis, Superstructure, Substructure and Design Optimisation.
Hover over the ⓘ icon next to any setting to see what it does.
Load Set
Load sets define the loads applied to the building in the structural checks. They're listed in the Loads table with these columns:
- Name – The load set in use by default is tagged
Default(e.g. Base Line).
- Description
- SDL (kPa) – Superimposed dead load.
- Live Load (kPa)
To add a load set: Click + Create New Loads and fill in the details.
To manage an existing load set: Click the three-dot icon (
⋮) on its row.
Structural Analysis
LFRS Criteria
Settings for the lateral force resisting system (LFRS):
- Turbulence Factor – 0 to 100, in increments of 5.
- Basic Wind Velocity – 0 to 50 m/s.
- Wind Directions – Select specific directions, or leave as All Wind Directions.
Structural Analysis Settings
- Heuristic Structural Solving in Site Space – Toggle on or off.
Analysis settings are set per element. Select Beam, Slab or Column to see its options.

Structural Systems
Structural systems are set under Superstructure.
- Choose a System type from the dropdown (e.g. System 7: Steel Composite Decking & Steel Column).
- Under Structural Products, select the element to configure: Beam, Slab, Wall, Joist, Column or StairCase.
- Adjust its settings e.g:
- Sizing – Min and max, each between 0 and 5 m.
- Suppliers – Select specific suppliers, or leave as All Suppliers.
- Product Types – Select specific product types, or leave as All Product Types.
- Limit solutions to chosen suppliers – Turn on to only use products from the suppliers you selected.

Foundation Systems
Foundation systems are set under Substructure.
- Choose a Foundation System from the dropdown (e.g. Deep Foundation (Bored Piles)).
- Select an element to configure
- Adjust its settings.

Soil Parameters
Soil parameters are set under Substructure, below the foundation settings.
- Allowable Soil Bearing Pressure – 10 to 1000 kPa. Only applies to shallow foundations.
Soil layers are entered. Each layer has:
- Depth – Enter the maximum depth of the layer.
- Stratum Thickness – Calculated automatically from the depths.
- SPT-N – 1 to 100.
- Ks – 1 to 10.
- Kb – 1 to 10.
Click + New Soil Layer to add another layer

Product Standardisation
Product standardisation is set under Design Optimisation → Modularisation. Select BeamModularisation or ColumnModularisation.
- Profile Standardisation – Toggle on or off.
- Target Percentage of Coverage of Standardisation – 50 to 95, in increments of 5.